Humidity
Operating/Storage
5 to 95% RH Non–condensing MIL-STD-810E,
Method 507.3 Procedure 1
Altitude
Operating: 0 to 42,000 ft. above sea level
Storage: 0 to 54,000 ft. above sea level
(MIL-STD-810E, Method 500.3)
Rapid Decompression
RTCA/DO-160D, 8,000 ft ASL to
42,000 ft. ASL in 15 seconds,
42,000 ft. ASL to 25,000 ft. ASL in 5 minutes
Shock
MIL-S-901D, Grade A, Class 1 Type A
Vibration
MIL-STD-167-1, Type 1
Drip Proof
MIL-STD-810E, Method 506.3 Procedure II, Front Panel only
Sand/Dust
MIL-STD-810E, Method 510.3,Front Panel only
EMI
MIL-STD-461E
CE101*, CE102, RE101*, RE102
CS101, CS114, CS116, RS101, RS103
* Pass with exception
Power Requirements
Power Supply
90-132/180-264 VAC Auto Ranging (+28 VDC Optional)
Frequency: 47-440 Hz
Power: 68 watts typical
Chassis Connector: IEC 320
Cable Connector: NEMA 5-15 P
Dimensions & Weight
Height: 15.75” (9U)
Width: 19.00”
Depth: 3.70”
Weight: 21.5 Lbs.
Compatibility
PCs, Workstations, & X-Terminals
Options
DVI-D, NTSC/S-Video Input,Brightness & Contrast Enhancements, Sunlight Readable
Touch Screens
Capacitive